1150kW Natural Gas Generator 480V 600V Waukesha 7044GSI

$0

New surplus 1150kW generator package with dual voltage capability (480V or 600V). Unit can run on either natural gas or propane. Ready to ship.

  • Waukesha 7044GSI gas engine, EPA Certified, 1200 rpm, continuous duty w/engine driven radiator assembly, enrolled in Waukesha engine preservation program
  • Kato Alternator, 1200KW, 6P6-3300, 6 Poles, 2 Bearing, 1200 rpm, 80 Deg C temp. rise, PMG, 600/480V dual Voltage, 0.8 PF, Renold coupling
  • Waukesha Engine ECU & Auxiliary I/O Box
  • Deep Sea 8610 Engine controller, start/stop/shutdown, sync, island, load share (other Deep Sea controllers) & utility parallel (adj. base load) modes of operation
  • 50 gallon oil make-up system with level indication
  • Inlet gas train with regulator, manual shutoff valve and solenoid, piped to outside of enclosure
  • 3-way exhaust catalyst and industrial exhaust silencer with heat blanket and exhaust flexible connection, exhaust stack w/extension and rain cap, structural frame to support catalyst and silencer
  • Engine skid recessed-mounted into working skid
  • Non-slip diamond plate floor
  • Base frame designed to accommodate drop over, weather resistant enclosure, lift-off frame, for (6) – point rig on/lift off from base/platform
  • Removable lifting eyes
  • Bolt-on connection to platform/base
  • Two (2) single access doors
  • One (1) double access door
  • Spill Containment for engine coolant & oil, Incorporated into working platform
  • Main circuit breaker, front access only through double doors on alternator end of genset, NEMA 3R rated, 2000AF insulated case circuit breaker, fixed mounted, 600/480VAC NEMA 3R, 65k AIC, UL891, LSIG trip, neutral sensor, 24VDC shunt trip, Form ‘C’ aux contacts, copper ground bus, metering CT’s and PT’s, open & close control by Deep Sea 8610 controller
  • Cable connection, 600/480V, 2000A – alternator output to main breaker, protected in steel wire way
  • Exterior cable connection, copper bus with NEMA pads/holes designed to accept customer cables and lugs, designed for cable entry from ground level, at side of enclosure near double doors
  • 480V to 120/208V transformer
  • 100A load center
  • Interior lighting, receptacles, and cable tray, convenience receptacles – GFCI, (1) double socket each side of gen container, (1) near breaker/control cabinet
  • DC emergency lighting each side of container, above access/escape doors with timer
  • Exterior lighting – (2) elevated lights to maintain light at ground level, pre-wired and installed but shipped loose
  • Light switches with weatherproof covers
  • Flush mount emergency stop with break glass NEMA 3R, shipped with extra contact blocks
  • SENS battery charger,  battery box with spill containment

Out of stock

Ask for more info on this item

Additional information

kw

voltage

,

manufacturer

model

condition

hours

year-built

fuel-type

,

cooling